Query Serving

Errors a users might encounter while querying Vitess

These error messages are internal to Vitess. If you are getting other errors from MySQL you can check them on this MySQL error page.
Error NumberError StateMessageMeaning
1105HY000INSERT not supported when targeting a key range: %sWhen targeting a range of shards, Vitess doesn't know which shard to send the INSERT to, so this is not supported.
1450HY000Changing schema from '%s' to '%s' is not allowedChanging schema from rename command is not valid
114942000aggregate functions take a single argument '%s'This function only takes a single argument.
1238HY000Variable '%s' is a read only variableTried changing a read-only system variable
1105HY000column has duplicate set values: '%v'Cannot assign multiple values to a column in an update statement
123142000unexpected value type for '%s': %vSome system variables require a specific type to be used
1192HY000Can't execute the given command because you have an active transactionThe provided statement cannot be executed inside a transaction.
123142000invalid transaction_mode: %sValid transaction_mode values are 'SINGLE', 'MULTI' or 'TWOPC'
123142000invalid workload: %sValid workload values are 'OLTP', 'OLAP' or 'DBA'
123142000invalid DDL strategy: %sValid DDL strategies are gh-ost, pt-osc
169022003%s value is out of range in %v [+,-,*,/] %vArithmetic operation lead to out of range value for the type
104742000connection ID and transaction ID do not existThe session is pointing to a transaction and/or reserved connection that is not valid
1105HY000%d is not a booleanTried setting a system variable to a value that could not be converted a boolean value
1105HY000%s is not a sequenceThe given table is not a sequence table
1105HY000%s: system setting is not supportedTried reading or setting a system variable that is not supported
1105HY000%v cannot be converted to a go typeThis type can't be represented as a golang value
1105HY0002pc is not enabledThis functionality requires 2PC. Read more about 'transaction_mode' to learn how to enable it.
1105HY000Destination can only be a single shard for statement: %s, got: %vThis statement type can only be executed against a single shard. You need to change the target string so a single shard in targeted.
1105HY000GTIDSet Mismatch: requested source position:%v, current target vrep position: %vThe requested GTIDSet does not exist in the vrep stream.
1105HY000No targetTODO https://github.com/vitessio/vitess/blob/9542883311c0849c645cfb1b5c77ac761990b31b/go/vt/vttablet/tabletserver/state_manager.go#L376
1105HY000Unexpected error, DestinationKeyspaceID mapping to multiple shardsThis is an internal error. If you see this error, please report it as a bug.
1105HY000auto sequence generation can happen through single shard only, it is getting routed to %d shardsA sequence query has to be routed to a single shard, but this query was not.
1105HY000cannot mix scope and user defined variablesIf you use the SET GLOBAL form, specify the variable without any @ symbols
1105HY000cannot use scope and @@If you use the SET GLOBAL form, specify the variable without any @ symbols
1105HY000column has duplicate set values: '%v'An UPDATE query should only list a column to be updated once
1105HY000could not parse value: '%s'Tried parsing a value as a number but failed
1105HY000disallowed due to rule: %sThe query was not permitted to execute because the session was lacking permissions to do so
1105HY000expression is too complex '%v'An expression was used that is not recognized by Vitess. Arithmetics and function calls are examples of expressions that are too complex in this context.
1105HY000invalid increment for sequence %s: %dTODO
1105HY000invalid keyspace %v does not match expected %vTODO
1105HY000invalid shard %v does not match expected %vTODO
1105HY000invalid table name: %sThe table name contains invalid characters
1105HY000is not a booleanThis error will be returned if you try to set a variable to a value that can't be converted to a boolean value.
1105HY000negative number cannot be converted to unsigned: %dThe column or variable is expecting an unsigned int, and negative numbers invalid here.
1105HY000query arguments missing for %sArgument expected but was missing.
1105HY000require autocommit to be 1: got %sConnection needs autocommit to be enabled, but it was not.
1105HY000require sql_auto_is_null to be 0: got %sVitess requires the connection not use the auto_col functionality
1105HY000require sql_mode to be STRICT_TRANS_TABLES or STRICT_ALL_TABLES: got '%s'Vitess requires the connection to be in STRICT mode; either or both of these settings need to be enabled.
1105HY000unexpected rows from reading sequence %s (possible mis-route): %dThe sequence table used returned invalid results.
1105HY000unsigned number overflows int64 value: %dTried to convert an unsigned integer into a signed integer, and the value overflows

Query Serving